• investigation of rigidity of shear tab connections in heavy steel girders

    جزئیات بیشتر مقاله
    • تاریخ ارائه: 1393/11/01
    • تاریخ انتشار در تی پی بین: 1393/11/01
    • تعداد بازدید: 526
    • تعداد پرسش و پاسخ ها: 0
    • شماره تماس دبیرخانه رویداد: -
     shear tab connection has proven to be economical and easy to erect. this kind of connection is assumed to be hinged connection by most of the designers. in this research, we have investigated the end rotation of the heavy steel girders with shear tab connection. the finite element software, ansys, has been used to determine the rigidity of shear tab connections. 125 models with different sizes of beam and tab plate were examined. results show that the rigidity of shear tab connection for heavy beams is high in compare with smaller beams and the hinged connection assumption may not be true for heavy beams with shear tab connection. the thickness and height of the shear tab plays a significant role in rigidity of connection at the end of the beam.