• problems and prospects connected with development of high-temperature filtration technology at nuclear power plants equipped with vver-1000 reactors

    نویسندگان :
    جزئیات بیشتر مقاله
    • تاریخ ارائه: 1392/07/24
    • تاریخ انتشار در تی پی بین: 1392/07/24
    • تعداد بازدید: 1057
    • تعداد پرسش و پاسخ ها: 0
    • شماره تماس دبیرخانه رویداد: -
     results of work on restoring the service properties of filtering material used in the high-temperature reactor coolant purification system of a vver-1000 reactor are presented. a quantitative assessment is given to the effect from subjecting a high-temperature sorbent to backwashing operations carried out with the use of regular capacities available in the design process circuit in the first years of operation of unit 3 at the kalinin nuclear power plant. approaches to optimizing this process are suggested. a conceptual idea about comprehensively solving the problem of achieving more efficient and safe operation of the high-temperature active water treatment system (awt-1) on a nuclear power industry-wide scale is outlined.